Zum Inhalt springen

FlickerSpec: LED Flicker Test

Audit, Compliance & Eye Strain

Entwickelt für iPhone

Kostenlos · In-App-Käufe

Bei App Store laden
  • Altersfreigabe4+
  • KategorieDienst­programme
  • EntwicklerCorey Thomas Slick
  • SprachenEnglisch
  • Größe11,7 MB

Verlinkt auf die offizielle App Store-Seite

Download.org hostet keine Datei von FlickerSpec: LED Flicker Test. Die Schaltfläche öffnet die App-Seite bei App Store, wo Corey Thomas Slick die App veröffentlicht. Eintrag zuletzt geprüft am 12.11.2026.

Screenshots

  • Screenshot von FlickerSpec: LED Flicker Test 1
  • Screenshot von FlickerSpec: LED Flicker Test 2
  • Screenshot von FlickerSpec: LED Flicker Test 3
  • Screenshot von FlickerSpec: LED Flicker Test 4
  • Screenshot von FlickerSpec: LED Flicker Test 5
  • Screenshot von FlickerSpec: LED Flicker Test 6
  • Screenshot von FlickerSpec: LED Flicker Test 7
  • Screenshot von FlickerSpec: LED Flicker Test 8
  • Screenshot von FlickerSpec: LED Flicker Test 9
  • Screenshot von FlickerSpec: LED Flicker Test 10

Info

Der Entwickler hat diesen Text nicht in Ihrer Sprache bereitgestellt.

Your new LEDs shouldn't be giving you headaches. If they are, the lights are almost certainly flickering — faster than your eyes can consciously detect, but fast enough to trigger migraines, eye strain, and fatigue. FlickerSpec turns your iPhone into a flicker meter, using the 240fps camera to measure exactly what your eyes can't.

For documentation — clinical engineering, facility management, lighting audits — FlickerSpec generates PDF reports that record the IEEE 1789 result and IEC PstLM value together with the standard, threshold, measurement uncertainty and calibration reference behind them. FlickerSpec is a screening and documentation aid, not an accredited laboratory instrument; whether a report satisfies a particular surveyor or regulator is their determination.

WHAT YOU MEASURE

Quick Measurement (Free, unlimited)
Live 240fps capture with real-time results:
• Dominant flicker frequency in Hz
• Percent Flicker and Flicker Index per IEEE 1789-2015
• Signal-to-noise ratio and confidence rating
• Live luminance waveform and FFT spectrum
• No daily limit — measure as many fixtures as you like

IEEE 1789 Verdicts (Pro)
Turn raw numbers into a documented decision:
• IEEE 1789-2015 verdict against the published low-risk practice: PASS, FAIL, or Can't confirm when the capture or framing cannot support a pass
• Custom pass/fail thresholds when your specification differs
• The standard and threshold applied are recorded with every saved measurement

3-Minute PstLM Measurement (Pro)
3-minute tripod capture for documenting low-frequency flicker:
• Short-Term Flicker Severity (PstLM) per IEC TR 61547-1:2015, for dominant frequencies up to 90 Hz
• Compared against the PstLM ≤ 1.0 limit cited by EU Ecodesign 2019/2020 (PstLM only — Ecodesign also requires SVM, beyond FlickerSpec's 240fps phone-camera pipeline)
• 8× oversampled LM flickermeter checked against all 5 IEC Table A.1 test vectors
• Camera-based measurement aid, not an accredited instrument or certified result

Measurement Logging & PDF Reports (Pro)
Every audit, documented:
• Save measurements with GPS location, fixture photo, and notes
• Single-measurement and session-summary PDF reports
• PstLM threshold-comparison section included when applicable
• Calibration certificate reference on every report
• CSV export for spreadsheet workflows

Calibration System (Free)
Verify accuracy before any audit:
• Built-in calibration web app generates a known-frequency reference signal
• Point your iPhone at any screen showing the calibration page
• Timestamped calibration certificate attached to all subsequent reports

MEASUREMENT BANDWIDTH

240fps camera capture (Nyquist: 120 Hz) is designed for 50 Hz mains regions:
• 50 Hz and 100 Hz flicker (50 Hz mains) — frequency and modulation depth
• 60 Hz and 120 Hz flicker (60 Hz mains, e.g. North America) — the dominant frequency may still be identifiable, but depth and the verdict that depends on it are conditional because 240 fps is an exact multiple of both. The app reports Can't confirm when it cannot sample the whole cycle.
• Above 120 Hz PWM and kHz drivers — outside camera bandwidth
• Modulation depth is a lower bound unless the light fills the region of interest

NO SUBSCRIPTIONS

$49.99 one-time purchase unlocks everything: IEEE 1789 risk indications, 3-Minute PstLM Measurement, unlimited logging, PDF reports, CSV export, the calibration certificate document, report header customization with your company name and logo.

Free tier: unlimited Quick Measurements with the full live readout — frequency, percent flicker, flicker index, SNR and confidence — plus free calibration.

Privacy Policy: https://flickerspec.slick-engineering.workers.dev/privacy
Terms of Use: https://flickerspec.slick-engineering.workers.dev/terms

Neue Funktionen

Version 1.5.0 · 19.09.2026

This release improves measurement interpretation and documentation:

• IEEE 1789 results now distinguish PASS, FAIL and Can't confirm when capture coverage or framing cannot support a pass.
• Calibration choices now match the companion website, including 144 Hz, 165 Hz and 240 Hz displays.
• User guidance and reports now explain the camera method's 60/120 Hz depth limitations and the scope of PstLM results more precisely.
• Includes reliability, privacy and report-formatting fixes.

App-Datenschutz

Was Corey Thomas Slick im App Store zum Umgang dieser App mit Daten angibt.

  • Keine Daten erfasst

    Der Entwickler erfasst keine Daten von dieser App.

Die Datenschutzpraktiken können variieren, zum Beispiel je nach den von Ihnen verwendeten Funktionen oder Ihrem Alter.

Informationen

Anbieter
Corey Thomas Slick
Kategorie
Dienst­programme
Version
1.5.0
Aktualisiert
19.09.2026
Veröffentlicht
03.04.2026
Größe
11,7 MB
Erfordert
iOS 26.0 oder neuer
Altersfreigabe
4+
Preis
Kostenlos
In-App-Käufe
Ja
Sprachen
Englisch
Copyright
© 2026 Slick Engineering & Consulting, Inc.