Skip to content

TTEView: Echo Scan Simulator

Physician-built TTE practice

Designed for iPhone, iPad

Free · In-app purchases

View in App Store
  • Age rating12+
  • CategoryMedical
  • DeveloperTOMOAKI TAKAKI
  • LanguagesEnglish+ 1 more
  • Size19.3 MB

Links to the official App Store page

Download.org hosts no file of TTEView: Echo Scan Simulator. The button opens its official App Store page, published by TOMOAKI TAKAKI. Listing last checked on Nov 24, 2026.

Screenshots

  • TTEView: Echo Scan Simulator screenshot 1
  • TTEView: Echo Scan Simulator screenshot 2
  • TTEView: Echo Scan Simulator screenshot 3
  • TTEView: Echo Scan Simulator screenshot 4
  • TTEView: Echo Scan Simulator screenshot 5
  • TTEView: Echo Scan Simulator screenshot 6
  • TTEView: Echo Scan Simulator screenshot 7
  • TTEView: Echo Scan Simulator screenshot 8
  • TTEView: Echo Scan Simulator screenshot 9
  • TTEView: Echo Scan Simulator screenshot 10

About

TTEView lets you practice the three steps of transthoracic echocardiography (TTE) on your iPhone, held sideways: finding the view, measuring, and grading.

BUILT AND SUPERVISED BY A PRACTICING PHYSICIAN
The scanning steps, the timing and position of each measurement, and the grading criteria are checked one by one against the guidelines and clinical practice.

A REAL 3D MODEL, TUNED FOR NORMAL ANATOMY
The normal heart was rebuilt for this app from real human anatomical data (Human Reference Atlas). Automatic checks cover the relations of the valves and chambers, papillary muscles and moderator band, continuous great vessels, and LV/RV volumes, wall thickness, LA size and RV diameters within ASE normal ranges, in all 20 frames of the beat.
The heartbeat follows the order of electrical activation. Change how you hold the probe, and the echo image of that plane is generated on the spot.

WHO IT IS FOR
- Beginners who want to find the standard views themselves
- Anyone practicing where and when to measure LVDd, Simpson's biplane, E/e' and TAPSE, through to guideline-based grading

SCANNING
- Choose an acoustic window on the body (left parasternal 3rd-5th intercostal spaces, apical, subcostal). Touch the right side of the screen to tilt the probe; swipe the left side to rotate it
- The frame turns green when you hit one of 11 standard views (PLAX, PSAX at four levels, apical 4-, 5-, 2- and 3-chamber, subcostal 4-chamber, IVC)
- When you are off, the app shows how far to rotate or tilt
- The echo image is formed the way ultrasound images are (scattering, beam width, specular reflection). Color Doppler shows the flow through the valves

MEASUREMENTS (27)
- LV: IVSd, LVDd, PWd, LVDs, Simpson's method (A4C and A2C), M-mode LVIDd/LVIDs with FS and EF (Teichholz)
- Diastolic function: E, A, DT, e' (septal and lateral), LA volume
- Right heart: TAPSE, TR velocity, PR velocity (early and end-diastolic), IVC diameter (expiration and inspiration)
- Hemodynamics: TR and PR gradients (4V²), RA pressure, PA systolic and diastolic pressure (≈ PCWP) and cardiac index, all the way to the Forrester class by echo
- Aortic valve: LVOT diameter, LVOT VTI, AV Vmax, AV VTI
- You place the M-mode line, the pulsed-wave Doppler gate and the continuous-wave line yourself. The waveform changes with your placement, and the app tells you whether the placement is right

CASE PRACTICE
- Scan hearts with myocardial infarction (wall-motion abnormalities by occlusion site, including RV infarction with proximal RCA occlusion) or valve disease (color Doppler of regurgitation and stenosis), then give your diagnosis
- After you answer, an explanation shows which segments and views reveal the findings

GRADING
- Based on ASE/EACVI 2015 (chamber quantification), ASE 2025 (diastolic function), ASE 2010 (right heart), ESC/ERS 2022 (pulmonary hypertension) and ACC/AHA 2020 (valvular heart disease)
- Reference values and sources (papers with DOIs) are available in the app

WHAT MAKES IT DIFFERENT
- You find each view with your own fingers (window, tilt, rotation) instead of jumping to it, with guidance on how far to move
- Measurements are scored against the correct value on the same image
- Anatomy mode (Pro): slice the real 3D model along the probe plane
- No network, no ads, no account. One-time purchase, not a subscription

FREE AND PRO
- Free: scanning (grading, guidance and "Show me" for all 11 views), the LVDd measurement, and LAD infarct cases in Case Practice
- Pro (one-time purchase): all 27 measurements, guideline-based grading, anatomy mode, all Case Practice cases and "Choose a case to view"

PLEASE NOTE
- The images and Doppler waveforms are simulated from a heart model. They are not images of real patients
- In Case Practice, 2D, M-mode and Doppler measurements and grading are scored against the case heart
- This app is for education. Do not use it for diagnostic or treatment decisions

What’s new

Version 1.0.4 · Nov 23, 2026

- Case Practice now supports measurements: 2D, M-mode and Doppler (PW, CW and tissue Doppler) on the case heart, with grading (diastolic function, pulmonary hypertension, echo-based Forrester class and more).
- Valve disease cases now show chronic changes: chamber dilatation, septal flattening, a dilated IVC, and LV wall thickening in aortic stenosis.
- In myocardial infarction cases, mitral inflow and tissue Doppler now change with infarct size and left atrial pressure.
- More realistic color Doppler: regurgitant and stenotic jets change shape from frame to frame, turbulence appears as a green mosaic, and a velocity color bar has been added.

App privacy

What TOMOAKI TAKAKI declares on the App Store about how this app handles data.

  • Data not collected

    The developer does not collect any data from this app.

Privacy practices may vary, for example with the features you use or your age.

Information

Seller
TOMOAKI TAKAKI
Category
Medical
Version
1.0.4
Updated
Nov 23, 2026
Released
Nov 4, 2026
Size
19.3 MB
Requires
iOS 17.0 or later
Age rating
12+
Price
Free
In-app purchases
Yes
Languages
English, Japanese
Copyright
© TOMOAKI TAKAKI