
- Yaş sınırı4+
- KategoriSağlık ve Fitness
- GeliştiriciBrainWave Software
- Dillerİngilizce
- Boyut76,2 MB
Resmi App Store sayfasına bağlanır
Download.org, PEER için hiçbir dosya barındırmaz. Düğme, uygulamanın App Store üzerindeki sayfasını açar; uygulamayı orada BrainWave Software yayınlar. Sayfanın son kontrolü: 14.11.2026.
Hakkında
Geliştirici bu metni dilinizde sunmamış.
PEER is an all-in-one EEG recording and ERP analysis App designed for research studies. PEER communicates with Brain Products X.on (Brain Products.com) EEG headset.
The PEER app collects raw EEG data and EEG data arising from Event-Related Potentials (ERP) neurological studies. The PEER app maintains a collection of "recordings". Each recording has a title and notes which can be searched. PEER displays summary information about the recording (sample rates, sizes, etc.).
The recorded EEG data can be exported in one of a number formats for analysis using MATLAB, BrainVision Analyzer or one of a number of other tools used by neuroscience researchers.
PEER includes the following games and features:
- Raw EEG recording and display
- Visual Oddball (passive, one-response, two-response)
- Audio Oddball (passive, one-response, two-response)
- N-Back
- Gambling Task
- Posner
- Image Presenter (select and preset custom images)
- One touch ERP analysis
- Export to Brain Vision Analyzer or .csv formats
PEER is not a diagnostic or medical device. PEER is for research use only.
Yenilikler
Sürüm 4.2.2 · 25.09.2026
4.2.2 Changes
- PEER 4.2 introduced a regression where some recordings were shown as recorded at 500Hz when they were actually recorded at 250Hz.
While PEER 4.2.1 corrected the underlying sample rate error, recordings made with PEER 4.2 displayed the incorrect 500Hz sample rate. PEER 4.2.2 corrects this error so that all recordings display their correct sample rate in the recording detail view. There is no impact on the underlying EEG data or marker placement.
This fix also addresses related problems with exports (BrainVision and PEER Archive), ERP analyses, quality analysis, and EEG chart timebases.
- Resolved a problem where PEER incorrectly recorded dropped samples when exiting the Signal Quality view. This view appears before each block of a game and in the Settings panel while an X.on is connected.
PEER tracks lost samples using a counter the X.on sends with each block of data. Every time the Signal Quality view appears, PEER takes the headset in and out of impedance mode, and the headset restarts that counter. PEER was reading the restart as roughly 65,000 lost samples. This is why affected recordings reported dropped samples when in fact there was no lost data.
For existing recordings made with PEER 4.2 and 4.2.1, you can ignore the displayed lost sample percentages. The EEG recorded during the trials is intact.
In each affected recording, one of these events wrote many seconds of empty samples into the file, between two blocks rather than inside one. In a BrainVision export, this shows up as a stretch of zeros across all channels. Marker positions are unaffected, so epoching around the block markers works as it should. To find the gap, look for a long run of exact zeros between two block start markers.
- BrainVision export now writes the correct sample rate for recordings made with PEER 4.2 that were incorrectly shown as 500Hz. Re-export any previously exported recordings to correct the sample rate.
- The dropped samples percentage shown for a recording now excludes samples dropped during the Signal Quality view.
- Improved the Signal Quality view to show ground and reference impedance.
- Improved the Signal Quality view to prevent false displays of the “No reference signal” warning.
- Resolved a problem where importing a PEER Archive set the recording’s build number to that of the version of PEER doing the import. Imported recordings now keep the build number of the version of PEER that made the recording.
- The signal quality display in the Settings panel, shown while connected to an X.on, now matches the Signal Quality view, including ground and reference impedance.
- The Bluetooth UUID is no longer shown in the EEG headbands list.
- Addressed a problem where the Select All/None, Share and Delete bottom toolbar buttons are missing when the Recordings View is in edit mode. This problem arises on iOS 26 and later.
PEER 4.2.1 Changes
- Resolved a problem where null EEG data was recorded during baseline recordings.
- Resolved a problem where X.on game recordings contained 250Hz data despite the application indicating the recordings contained 500Hz data. This problem did not affect raw EEG recordings.
The problem occurred when PEER’s Signal Quality view placed the X.on in Impedance mode, where the X.on switches to a 250Hz sample rate. When the Signal Quality view was dismissed, PEER returned the device to EEG mode but failed to switch it back to 500Hz.
- Improved impedance displays in the Signal Quality view.
- Improved detail view appearance under iOS Liquid Glass (iOS 26 and later).
- Internal code cleanup.
Uygulama gizliliği
Bu uygulamanın verileri nasıl işlediği hakkında BrainWave Software tarafından App Store üzerinde yapılan beyan.
-
Veri toplanmıyor
Geliştirici bu uygulamadan hiçbir veri toplamıyor.
Gizlilik uygulamaları, örneğin kullandığınız özelliklere veya yaşınıza göre değişiklik gösterebilir.
Bilgiler
- Satıcı
- BrainWave Software Inc.
- Kategori
- Sağlık ve Fitness
- Sürüm
- 4.2.2
- Güncellendi
- 25.09.2026
- Yayın tarihi
- 14.07.2022
- Boyut
- 76,2 MB
- Gereksinim
- iOS 17.6 veya sonrası
- Yaş sınırı
- 4+
- Fiyat
- Ücretsiz
- Diller
- İngilizce
- Telif hakkı
- © BrainWave Software Inc., 2026
Bunları da beğenebilirsiniz
-
Antares BioSync UnitSağlık ve Fitness
-
Five Elements HarmonySağlık ve Fitness
-
eVu SenzTıp
-
Multiple Sclerosis TrackerMS belirti ve atak gunlugu
-
Dive Brain HealthSağlık ve Fitness
-
MemScreenTıp
-
Medicalholodeck®Tıp, Anatomi, Cerrahi
-
Theta Waves: Binaural BeatsSağlık ve Fitness
-
FitlightSağlık ve Fitness
-
Breathr: Mindful MomentsSağlık ve Fitness






