Nuclear Toolkit
iPhone, iPad için tasarlandı
Ücretsiz · Uygulama içi satın alma
- Yaş sınırı4+
- KategoriReferans
- GeliştiriciTIMOTHY ALEXANDER COFFMAN
- Dillerİngilizce
- Boyut42,5 MB
Resmi App Store sayfasına bağlanır
Download.org, Nuclear Toolkit için hiçbir dosya barındırmaz. Düğme, uygulamanın App Store üzerindeki sayfasını açar; uygulamayı orada TIMOTHY ALEXANDER COFFMAN yayınlar. Sayfanın son kontrolü: 17.11.2026.
Hakkında
Geliştirici bu metni dilinizde sunmamış.
Nuclear Toolkit is an offline engineering reference and calculator for nuclear
professionals and students. No account, login, or network connection is required —
all datasets are bundled with the app.
The app performs radiation dose and shielding calculations. It is an engineering
reference tool, not a medical device, and is not intended for patient diagnosis or
treatment. A persistent disclaimer appears on every calculator screen stating it is
for educational and reference purposes and is not a substitute for qualified health
physics or nuclear engineering analysis.
All nuclear data comes from public authorities and is attributed on-screen: IAEA
Nuclear Data Services (NUBASE2020, AME2020, ENSDF), NIST Standard Reference
Database 126, and PubChem (NIH). Formulas cite Lamarsh & Baratta and Duderstadt &
Hamilton with section numbers.
No in-app purchases in this version. No user-generated content, no social features. There is a Tip Jar which would be appreciated.
Anonymous usage analytics only, disclosed in the in-app privacy policy.
Terms of Use: https://www.apple.com/legal/internet-services/itunes/dev/stdeula/
Yenilikler
Sürüm 1.4.1 · 05.10.2026
## **Shielding, corrected**
* **Buildup factors now use ANSI/ANS-6.4.3** for each shield material — lead, tungsten, tin, copper, iron, aluminium, concrete, and water — across **15 keV–15 MeV**, applied according to the standard.
The previous factors stopped at 0.5 MeV and substituted data between materials. **Dose behind thick lead was therefore underestimated:** the Cs-137 dose behind 10 cm of lead was about half the corrected value, and the 5 cm result was about 25% low. For a low-energy source in water, the result was up to 2× too low.
* **New: optional air attenuation and scatter.** Air between the source and detector can now be included using the corresponding standard data. This is particularly useful near radiography boundaries. It is **off by default**, since published dose constants generally assume vacuum.
## **Neutron activation, corrected**
* **Fast-neutron reaction rates now use the IAEA IRDFF-II library**, averaged over the spectrum of the selected source: reactor fission neutrons, Am-Be, or D-D/D-T generators.
For Am-Be, the previous Fe-54(n,p) result was **3.4× too low**; for a reactor spectrum, O-16(n,p) was **43% too low**.
* **New fast-flux monitors:** Ni-58(n,p)Co-58, Ti-46(n,p)Sc-46, S-32(n,p)P-32, and Cu-63(n,α)Co-60, plus a **D-T neutron-generator source**.
**Every calculator and dataset remains free.**
Uygulama gizliliği
Bu uygulamanın verileri nasıl işlediği hakkında TIMOTHY ALEXANDER COFFMAN tarafından App Store üzerinde yapılan beyan.
-
Sizinle ilişkilendirilmeyen veriler
Toplanabilir ancak kimliğinizle ilişkilendirilmez.
- Konum
- Tanımlayıcılar
- Kullanım verileri
Gizlilik uygulamaları, örneğin kullandığınız özelliklere veya yaşınıza göre değişiklik gösterebilir.
Bilgiler
- Satıcı
- TIMOTHY ALEXANDER COFFMAN
- Kategori
- Referans
- Sürüm
- 1.4.1
- Güncellendi
- 05.10.2026
- Yayın tarihi
- 30.08.2026
- Boyut
- 42,5 MB
- Gereksinim
- iOS 16.4 veya sonrası
- Yaş sınırı
- 4+
- Fiyat
- Ücretsiz
- Uygulama içi satın alma
- Evet
- Diller
- İngilizce
- Telif hakkı
- © 2026 Timothy Coffman