Nuclear Toolkit
Được thiết kế cho iPhone, iPad
Miễn phí · Mua hàng trong ứng dụng
- Độ tuổi4+
- Danh mụcTham Khảo
- Nhà phát triểnTIMOTHY ALEXANDER COFFMAN
- Ngôn ngữTiếng Anh
- Kích thước42,5 MB
Liên kết đến trang App Store chính thức
Download.org không lưu trữ tệp nào của Nuclear Toolkit. Nút này mở trang ứng dụng trên App Store, nơi TIMOTHY ALEXANDER COFFMAN phát hành ứng dụng. Trang được kiểm tra lần cuối: 17/11/2026.
Giới thiệu
Nhà phát triển chưa cung cấp nội dung này bằng ngôn ngữ của bạn.
Nuclear Toolkit is an offline engineering reference and calculator for nuclear
professionals and students. No account, login, or network connection is required —
all datasets are bundled with the app.
The app performs radiation dose and shielding calculations. It is an engineering
reference tool, not a medical device, and is not intended for patient diagnosis or
treatment. A persistent disclaimer appears on every calculator screen stating it is
for educational and reference purposes and is not a substitute for qualified health
physics or nuclear engineering analysis.
All nuclear data comes from public authorities and is attributed on-screen: IAEA
Nuclear Data Services (NUBASE2020, AME2020, ENSDF), NIST Standard Reference
Database 126, and PubChem (NIH). Formulas cite Lamarsh & Baratta and Duderstadt &
Hamilton with section numbers.
No in-app purchases in this version. No user-generated content, no social features. There is a Tip Jar which would be appreciated.
Anonymous usage analytics only, disclosed in the in-app privacy policy.
Terms of Use: https://www.apple.com/legal/internet-services/itunes/dev/stdeula/
Có gì mới
Phiên bản 1.4.1 · 05/10/2026
## **Shielding, corrected**
* **Buildup factors now use ANSI/ANS-6.4.3** for each shield material — lead, tungsten, tin, copper, iron, aluminium, concrete, and water — across **15 keV–15 MeV**, applied according to the standard.
The previous factors stopped at 0.5 MeV and substituted data between materials. **Dose behind thick lead was therefore underestimated:** the Cs-137 dose behind 10 cm of lead was about half the corrected value, and the 5 cm result was about 25% low. For a low-energy source in water, the result was up to 2× too low.
* **New: optional air attenuation and scatter.** Air between the source and detector can now be included using the corresponding standard data. This is particularly useful near radiography boundaries. It is **off by default**, since published dose constants generally assume vacuum.
## **Neutron activation, corrected**
* **Fast-neutron reaction rates now use the IAEA IRDFF-II library**, averaged over the spectrum of the selected source: reactor fission neutrons, Am-Be, or D-D/D-T generators.
For Am-Be, the previous Fe-54(n,p) result was **3.4× too low**; for a reactor spectrum, O-16(n,p) was **43% too low**.
* **New fast-flux monitors:** Ni-58(n,p)Co-58, Ti-46(n,p)Sc-46, S-32(n,p)P-32, and Cu-63(n,α)Co-60, plus a **D-T neutron-generator source**.
**Every calculator and dataset remains free.**
Quyền riêng tư của ứng dụng
Những gì TIMOTHY ALEXANDER COFFMAN khai báo trên App Store về cách ứng dụng này xử lý dữ liệu.
-
Dữ liệu không liên kết với bạn
Có thể được thu thập nhưng không liên kết với danh tính của bạn.
- Vị trí
- Mã định danh
- Dữ liệu sử dụng
Phương thức đảm bảo quyền riêng tư có thể khác nhau, chẳng hạn như tuỳ theo các tính năng bạn sử dụng hoặc độ tuổi của bạn.
Thông tin
- Người bán
- TIMOTHY ALEXANDER COFFMAN
- Danh mục
- Tham Khảo
- Phiên bản
- 1.4.1
- Cập nhật
- 05/10/2026
- Phát hành
- 30/08/2026
- Kích thước
- 42,5 MB
- Yêu cầu
- iOS 16.4 trở lên
- Độ tuổi
- 4+
- Giá
- Miễn phí
- Mua hàng trong ứng dụng
- Có
- Ngôn ngữ
- Tiếng Anh
- Bản quyền
- © 2026 Timothy Coffman



















